CXT 19 AtC coaxial cable Dca Euroclass, A Class shielded

RG-6 coaxial cable with copper inner conductor and aluminium braid (Cu/Al), and an excellent braid coverage (79%). A 19 AtC cable with double shielded and LSFH sheath.

Ref. 212811
EAN13: 8424450169834
Highlights
  • Copper inner conductor and aluminium braid
  • Class A shielded
  • Dca-s2,d2,a1 Euroclass

Main features
  • Grey-colour external LSFH sheath
  • 75 Ohm characteristic impedance
  • 250 m wood reel

Discover

Double-shielded Class A coaxial cable

With 2 shielding layers, these cables provide an outstanding shielding thanks to a high-coverage braid.

They belong in EN 50117 standard Class A, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 5 mΩ/m
  • For 30 MHz - 1000 MHz => SA > 85 dB
  • For 1000 MHz - 2000 MHz => SA > 75 dB
  • For 2000 MHz - 3000 MHz => SA > 65 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.


ModelCXT
Cable typeRG-6
StandardEN 50117-9-2
EuroclassDca
Euroclass: Smoke Productions2
Euroclass: Flaming dropletsd2
Euroclass: Aciditya1
ClassA
Inner conductor Diametermm1
Inner conductor MaterialCopper (Cu)
Inner conductor ResistanceOhm/km < 23
Dielectric Diametermm4.5
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorWhite RAL 9003
Overlapped foilAluminium + Polyester
Braid MaterialAluminium
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)8
Braid Dimensions: strand diameter (Ø)mm0.12
Braid ResistanceOhm/km < 31
Braid Coverage%79
2nd foilNo
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmNo
Outer sheath Diametermm6.5
Outer sheath MaterialLSFH
Minimum bending radiusmm32.5
Transfer impedance (5-30MHz)mΩ /m < 5
1GHz shieldingdB > 85
Spark TestVac3000
CapacitancepF/m54
ImpedanceΩ75
Velocity ratio%82
Operating temperature°C -25 ... 70
Frequencies
5 MHz47 MHz54 MHz90 MHz200 MHz500 MHz698 MHz800 MHz862 MHz950 MHz1000 MHz1220 MHz1350 MHz1750 MHz2050 MHz2150 MHz2200 MHz2300 MHz2400 MHz3000 MHz
Attenuation (typ.)dB/m
0.01 0.04 0.05 0.06 0.09 0.14 0.17 0.19 0.19 0.2 0.21 0.23 0.25 0.29 0.32 0.33 0.35 0.35 0.35 0.39
Return losses (min.)dB
20 20 20 20 20 18 18 18 18 18 18 16 16 16 15 15 15 15 15 15

Physical data

Net weight: 40 g

Gross weight: 40 g

Width: 6 mm

Height: 1,000 mm

Depth: 6 mm

Main product weight: 39 g

Packing

Reel 250 m

Pallet 7500 m

Pallet 9000 m

More Information
tlv_tags

Double-shielded Class A coaxial cable

With 2 shielding layers, these cables provide an outstanding shielding thanks to a high-coverage braid.

They belong in EN 50117 standard Class A, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 5 mΩ/m
  • For 30 MHz - 1000 MHz => SA > 85 dB
  • For 1000 MHz - 2000 MHz => SA > 75 dB
  • For 2000 MHz - 3000 MHz => SA > 65 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.

tlv_caracteristicas_ficha

Cable coaxial de doble capa y Clase A

Con 2 capas de blindaje, estos cables ofrecen un buen apantallamiento gracias a una malla de gran cobertura.

Sus propiedades constructivas los hacen Clase A, cumpliendo según la norma EN 50117:

  • A 5 - 30 MHz => TI < 5 mΩ/m
  • A 5 - 1000 MHz => SA > 85 dB
  • A 1000 - 2000 MHz => SA > 75 dB
  • A 2000 - 3000 MHz => SA > 65 dB

Dónde, la impedancia de transferencia (TI) define la efectividad del apantallamiento a bajas frecuencias, y la atenuación del apantallamiento (SA) la define entre 30 y 3000MHz.

tlv_tabla_especificaciones
ModelCXT
Cable typeRG-6
StandardEN 50117-9-2
EuroclassDca
Euroclass: Smoke Productions2
Euroclass: Flaming dropletsd2
Euroclass: Aciditya1
ClassA
Inner conductor Diametermm1
Inner conductor MaterialCopper (Cu)
Inner conductor ResistanceOhm/km < 23
Dielectric Diametermm4.5
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorWhite RAL 9003
Overlapped foilAluminium + Polyester
Braid MaterialAluminium
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)8
Braid Dimensions: strand diameter (Ø)mm0.12
Braid ResistanceOhm/km < 31
Braid Coverage%79
2nd foilNo
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmNo
Outer sheath Diametermm6.5
Outer sheath MaterialLSFH
Minimum bending radiusmm32.5
Transfer impedance (5-30MHz)mΩ /m < 5
1GHz shieldingdB > 85
Spark TestVac3000
CapacitancepF/m54
ImpedanceΩ75
Velocity ratio%82
Operating temperature°C -25 ... 70
Frequencies
5 MHz47 MHz54 MHz90 MHz200 MHz500 MHz698 MHz800 MHz862 MHz950 MHz1000 MHz1220 MHz1350 MHz1750 MHz2050 MHz2150 MHz2200 MHz2300 MHz2400 MHz3000 MHz
Attenuation (typ.)dB/m
0.01 0.04 0.05 0.06 0.09 0.14 0.17 0.19 0.19 0.2 0.21 0.23 0.25 0.29 0.32 0.33 0.35 0.35 0.35 0.39
Return losses (min.)dB
20 20 20 20 20 18 18 18 18 18 18 16 16 16 15 15 15 15 15 15
tlv_ean 8424450169834
tlv_dim_product_x 6
tlv_dim_product_x_label Width
tlv_dim_product_x_unit mm
tlv_dim_product_y 1,000
tlv_dim_product_y_label Height
tlv_dim_product_y_unit mm
tlv_dim_product_z 6
tlv_dim_product_z_label Depth
tlv_dim_product_z_unit mm
tlv_weight_product_label Main product weight
tlv_weight_product 39
tlv_weight_product_unit g
tlv_gross_weight_label Gross weight
tlv_gross_weight 40
tlv_gross_weight_unit g
tlv_net_weight_label Net weight
tlv_net_weight_unit g
tlv_net_weight 40
tlv_1_type_pack Reel
tlv_1_type_pcs_pack m
tlv_1_pcs_pack 250
tlv_2_pcs_pack 7500
tlv_2_type_pack Pallet
tlv_2_type_pcs_pack m
tlv_3_pcs_pack 9000
tlv_3_type_pack Pallet
tlv_3_type_pcs_pack m

Mounting details

DETAIL VIEW OF THE COAXIAL CABLE SECTION

A-Inner conductor
B-Dielectric
C-Foil
D-Braid
E-Outer sheath

Cookies use

We use our own cookies and those of third parties to analyze the use and metrics of our web. You can change settings, accept or reject the use of cookies by clicking on the next button.

For more information, click on our Cookies Policy.