The wishlist name can't be left blank

T100plus 16 VRtC coaxial cable Eca Euroclass

RG-6 coaxial cable with both conductors made of copper (Cu/Cu), double shielded, and anti-migrating film. A 16 VRtC cable with PVC sheath.

Ref. 2141
Product Sheet
EAN13: 8424450021415
SKU
2141
Highlights
  • Copper conductors
  • Eca Euroclass
  • The anti-migrating film prevents sheath's additive agents and humidity migration to the inner cable, thus avoiding deterioration in the characteristics

Main features
  • White-colour external PVC sheath
  • 75 Ohm characteristic impedance
  • 100 m plastic reel

Discover

Double-shielded Class B coaxial cable

They provide two shielding layers and belong in EN 50117 standard Class B, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 15 mΩ/m
  • For 30 MHz - 1000 MHz => SA > 75 dB
  • For 1000 MHz - 2000 MHz => SA > 65 dB
  • For 2000 MHz - 3000 MHz => SA > 55 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.


ModelT-100plus
Cable typeRG-6
StandardEN 50117-9-2
EuroclassEca
ClassB
Inner conductor Diametermm1.13
Inner conductor MaterialCopper (Cu)
Inner conductor ResistanceΩ/km < 20
Dielectric Diametermm4.8
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorWhite RAL 9003
Overlapped foilCopper + Polyester
Braid MaterialCopper
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)4
Braid Dimensions: strand diameter (Ø)mm0.1
Braid ResistanceΩ/km < 20
Braid Coverage%38
2nd foilNo
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmYes
Outer sheath Diametermm6.6
Outer sheath MaterialPVC
Minimum bending radiusmm33
Transfer impedance (5-30MHz)mΩ/m < 15
1GHz shieldingdB > 75
Spark TestVac3000
CapacitancepF/m55
ImpedanceΩ75
Velocity ratio%82
Operating temperature°C -30 ... 70
Frequencies
5 MHz47 MHz54 MHz90 MHz200 MHz500 MHz698 MHz800 MHz862 MHz950 MHz1000 MHz1220 MHz1350 MHz1750 MHz2050 MHz2150 MHz2200 MHz2300 MHz2400 MHz3000 MHz
Attenuation (typ.)dB/m
0.01 0.04 0.04 0.05 0.08 0.13 0.15 0.16 0.17 0.18 0.19 0.2 0.22 0.25 0.26 0.27 0.28 0.29 0.3 0.33
Return losses (min.)dB
23 23 23 23 23 20 20 20 20 20 20 18 18 18 16 16 16 16 16 16

Physical data

Net weight: 47 g

Gross weight: 47 g

Width: 8 mm

Height: 1,000 mm

Depth: 8 mm

Main product weight: 44 g

Packing

Reel 100 m

Box 500 m

Pallet 6000 m

More Information
tlv_tags

Double-shielded Class B coaxial cable

They provide two shielding layers and belong in EN 50117 standard Class B, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 15 mΩ/m
  • For 30 MHz - 1000 MHz => SA > 75 dB
  • For 1000 MHz - 2000 MHz => SA > 65 dB
  • For 2000 MHz - 3000 MHz => SA > 55 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.

tlv_caracteristicas_ficha

Cable coaxial de doble capa y Clase B

Ofrecen 2 capas de blindaje y su propiedades constructivas los hacen Clase B, cumpliendo según la norma EN 50117:

  • A 5 - 30 MHz => TI < 15 mΩ/m
  • A 5 - 1000 MHz => SA > 75 dB
  • A 1000 - 2000 MHz => SA > 65 dB
  • A 2000 - 3000 MHz => SA > 55 dB

Dónde, la impedancia de transferencia (TI) define la efectividad del apantallamiento a bajas frecuencias, y la atenuación del apantallamiento (SA) la define entre 30 y 3000MHz.

tlv_reflog KK1148
tlv_tabla_especificaciones
ModelT-100plus
Cable typeRG-6
StandardEN 50117-9-2
EuroclassEca
ClassB
Inner conductor Diametermm1.13
Inner conductor MaterialCopper (Cu)
Inner conductor ResistanceΩ/km < 20
Dielectric Diametermm4.8
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorWhite RAL 9003
Overlapped foilCopper + Polyester
Braid MaterialCopper
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)4
Braid Dimensions: strand diameter (Ø)mm0.1
Braid ResistanceΩ/km < 20
Braid Coverage%38
2nd foilNo
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmYes
Outer sheath Diametermm6.6
Outer sheath MaterialPVC
Minimum bending radiusmm33
Transfer impedance (5-30MHz)mΩ/m < 15
1GHz shieldingdB > 75
Spark TestVac3000
CapacitancepF/m55
ImpedanceΩ75
Velocity ratio%82
Operating temperature°C -30 ... 70
Frequencies
5 MHz47 MHz54 MHz90 MHz200 MHz500 MHz698 MHz800 MHz862 MHz950 MHz1000 MHz1220 MHz1350 MHz1750 MHz2050 MHz2150 MHz2200 MHz2300 MHz2400 MHz3000 MHz
Attenuation (typ.)dB/m
0.01 0.04 0.04 0.05 0.08 0.13 0.15 0.16 0.17 0.18 0.19 0.2 0.22 0.25 0.26 0.27 0.28 0.29 0.3 0.33
Return losses (min.)dB
23 23 23 23 23 20 20 20 20 20 20 18 18 18 16 16 16 16 16 16
tlv_ean 8424450021415
tlv_dim_product_x 8
tlv_dim_product_x_label Width
tlv_dim_product_x_unit mm
tlv_dim_product_y 1,000
tlv_dim_product_y_label Height
tlv_dim_product_y_unit mm
tlv_dim_product_z 8
tlv_dim_product_z_label Depth
tlv_dim_product_z_unit mm
tlv_weight_product_label Main product weight
tlv_weight_product 44
tlv_weight_product_unit g
tlv_gross_weight_label Gross weight
tlv_gross_weight 47
tlv_gross_weight_unit g
tlv_net_weight_label Net weight
tlv_net_weight_unit g
tlv_net_weight 47
tlv_1_type_pack Reel
tlv_1_type_pcs_pack m
tlv_1_pcs_pack 100
tlv_2_pcs_pack 500
tlv_2_type_pack Box
tlv_2_type_pcs_pack m
tlv_3_pcs_pack 6000
tlv_3_type_pack Pallet
tlv_3_type_pcs_pack m

Mounting details

DETAIL VIEW OF THE COAXIAL CABLE SECTION

A-Inner conductor
B-Dielectric
C-Foil
D-Braid
E- Anti-migrating film
F-Outer sheath