The wishlist name can't be left blank

CXT 18C coaxial cable Dca Euroclass

RG-6 coaxial cable with copper inner conductor and copper-clad aluminium braid (Cu/CCA), double shielded. A 18C cable with LSFH sheath. It includes an anti-migrating film that makes easier the cable stripping process by avoiding damage to the braid, as well as preventing deterioration of the interior of the cable.

In stock
SKU
2142xx_coaxial_CXT
Select your product
Grouped product items
Ref. 214210 Colour: White, Reel type: Wrapped coil, Length: 100 m
Ref. 214211 Colour: White, Reel type: Wrapped coil, Length: 250 m
Ref. 213910 Colour: Black, Reel type: Wrapped coil, Length: 100 m
Product Sheet
Highlights
  • Copper inner conductor and copper-clad aluminium braid
  • Dca-s2,d2,a2 Euroclass
  • The anti-migrating film prevents sheath's additive agents and humidity migration to the inner cable, thus avoiding deterioration in the characteristics

Main features
  • External LSFH sheath
  • 75 Ohm characteristic impedance
  • Wrapped coil

Discover

Double-shielded Class B coaxial cable

They provide two shielding layers and belong in EN 50117 standard Class B, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 15 mΩ/m
  • For 30 MHz - 1000 MHz => SA > 75 dB
  • For 1000 MHz - 2000 MHz => SA > 65 dB
  • For 2000 MHz - 3000 MHz => SA > 55 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.


Ref. 214210
ModelCXT
Cable typeRG-6
StandardEN 50117-9-2
EuroclassDca
Euroclass: Smoke Productions2
Euroclass: Flaming dropletsd2
Euroclass: Aciditya2
ClassB
Inner conductor Diametermm1
Inner conductor MaterialCopper (Cu)
Inner conductor ResistanceΩ/km < 23
Dielectric Diametermm4.8
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorWhite RAL 9003
Overlapped foilCopper + Polyester
Braid MaterialAluminium + Copper
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)3
Braid Dimensions: strand diameter (Ø)mm0.12
Braid ResistanceΩ/km < 35
Braid Coverage%35
2nd foilNo
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmYes
Outer sheath Diametermm6.6
Outer sheath MaterialLSFH
Minimum bending radiusmm33
Transfer impedance (5-30MHz)mΩ/m < 15
1GHz shieldingdB > 75
Spark TestVac3000
CapacitancepF/m55
ImpedanceΩ75
Velocity ratio%82
Operating temperature°C -25 ... 70
Frequencies
5 MHz47 MHz54 MHz90 MHz200 MHz500 MHz698 MHz800 MHz862 MHz950 MHz1000 MHz1220 MHz1350 MHz1750 MHz2050 MHz2150 MHz2200 MHz2300 MHz2400 MHz3000 MHz
Attenuation (typ.)dB/m
0.01 0.05 0.05 0.06 0.09 0.14 0.16 0.18 0.19 0.2 0.2 0.22 0.24 0.28 0.3 0.31 0.31 0.31 0.33 0.36
Return losses (min.)dB
23 23 23 23 23 20 20 20 20 20 20 18 18 18 16 16 16 16 16 16

Physical data

Net weight: 38 g

Gross weight: 40 g

Width: 7 mm

Height: 1,000 mm

Depth: 7 mm

Main product weight: 38 g

Packing

Coil 100 m

Pallet 6000 m

Ref. 214211
ModelCXT
Cable typeRG-6
StandardEN 50117-9-2
EuroclassDca
Euroclass: Smoke Productions2
Euroclass: Flaming dropletsd2
Euroclass: Aciditya2
ClassB
Inner conductor Diametermm1
Inner conductor MaterialCopper (Cu)
Inner conductor ResistanceΩ/km < 23
Dielectric Diametermm4.8
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorWhite RAL 9003
Overlapped foilCopper + Polyester
Braid MaterialAluminium + Copper
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)3
Braid Dimensions: strand diameter (Ø)mm0.12
Braid ResistanceΩ/km < 35
Braid Coverage%35
2nd foilNo
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmYes
Outer sheath Diametermm6.6
Outer sheath MaterialLSFH
Minimum bending radiusmm33
Transfer impedance (5-30MHz)mΩ/m < 15
1GHz shieldingdB > 75
Spark TestVac3000
CapacitancepF/m55
ImpedanceΩ75
Velocity ratio%82
Operating temperature°C -25 ... 70
Frequencies
5 MHz47 MHz54 MHz90 MHz200 MHz500 MHz698 MHz800 MHz862 MHz950 MHz1000 MHz1220 MHz1350 MHz1750 MHz2050 MHz2150 MHz2200 MHz2300 MHz2400 MHz3000 MHz
Attenuation (typ.)dB/m
0.01 0.05 0.05 0.06 0.09 0.14 0.16 0.18 0.19 0.2 0.2 0.22 0.24 0.28 0.3 0.31 0.31 0.31 0.33 0.36
Return losses (min.)dB
23 23 23 23 23 20 20 20 20 20 20 18 18 18 16 16 16 16 16 16

Physical data

Net weight: 38 g

Gross weight: 40 g

Width: 7 mm

Height: 1,000 mm

Depth: 7 mm

Main product weight: 38 g

Packing

Coil 250 m

Pallet 6000 m

Ref. 213910
ModelCXT
Cable typeRG-6
StandardEN 50117-9-2
EuroclassDca
Euroclass: Smoke Productions2
Euroclass: Flaming dropletsd2
Euroclass: Aciditya2
ClassB
Inner conductor Diametermm1
Inner conductor MaterialCopper (Cu)
Inner conductor ResistanceΩ/km < 23
Dielectric Diametermm4.8
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorWhite RAL 9003
Overlapped foilCopper + Polyester
Braid MaterialAluminium + Copper
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)3
Braid Dimensions: strand diameter (Ø)mm0.12
Braid ResistanceΩ/km < 35
Braid Coverage%35
2nd foilNo
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmYes
Outer sheath Diametermm6.6
Outer sheath MaterialLSFH
Minimum bending radiusmm33
Transfer impedance (5-30MHz)mΩ/m < 15
1GHz shieldingdB > 75
Spark TestVac3000
CapacitancepF/m55
ImpedanceΩ75
Velocity ratio%82
Operating temperature°C -25 ... 70
Frequencies
5 MHz47 MHz54 MHz90 MHz200 MHz500 MHz698 MHz800 MHz862 MHz950 MHz1000 MHz1220 MHz1350 MHz1750 MHz2050 MHz2150 MHz2200 MHz2300 MHz2400 MHz3000 MHz
Attenuation (typ.)dB/m
0.01 0.05 0.05 0.06 0.09 0.14 0.16 0.18 0.19 0.2 0.2 0.22 0.24 0.28 0.3 0.31 0.31 0.31 0.33 0.36
Return losses (min.)dB
23 23 23 23 23 20 20 20 20 20 20 18 18 18 16 16 16 16 16 16

Physical data

Net weight: 40 g

Gross weight: 43 g

Width: 1,000 mm

Height: 7 mm

Depth: 7 mm

Packing

Reel 100 m

Box 500 m

Pallet 6000 m

More Information
tlv_tags

Double-shielded Class B coaxial cable

They provide two shielding layers and belong in EN 50117 standard Class B, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 15 mΩ/m
  • For 30 MHz - 1000 MHz => SA > 75 dB
  • For 1000 MHz - 2000 MHz => SA > 65 dB
  • For 2000 MHz - 3000 MHz => SA > 55 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.

tlv_tabla_especificaciones
ModelCXT
Cable typeRG-6
StandardEN 50117-9-2
EuroclassDca
Euroclass: Smoke Productions2
Euroclass: Flaming dropletsd2
Euroclass: Aciditya2
ClassB
Inner conductor Diametermm1
Inner conductor MaterialCopper (Cu)
Inner conductor ResistanceΩ/km < 23
Dielectric Diametermm4.8
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorWhite RAL 9003
Overlapped foilCopper + Polyester
Braid MaterialAluminium + Copper
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)3
Braid Dimensions: strand diameter (Ø)mm0.12
Braid ResistanceΩ/km < 35
Braid Coverage%35
2nd foilNo
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmYes
Outer sheath Diametermm6.6
Outer sheath MaterialLSFH
Minimum bending radiusmm33
Transfer impedance (5-30MHz)mΩ/m < 15
1GHz shieldingdB > 75
Spark TestVac3000
CapacitancepF/m55
ImpedanceΩ75
Velocity ratio%82
Operating temperature°C -25 ... 70
Frequencies
5 MHz47 MHz54 MHz90 MHz200 MHz500 MHz698 MHz800 MHz862 MHz950 MHz1000 MHz1220 MHz1350 MHz1750 MHz2050 MHz2150 MHz2200 MHz2300 MHz2400 MHz3000 MHz
Attenuation (typ.)dB/m
0.01 0.05 0.05 0.06 0.09 0.14 0.16 0.18 0.19 0.2 0.2 0.22 0.24 0.28 0.3 0.31 0.31 0.31 0.33 0.36
Return losses (min.)dB
23 23 23 23 23 20 20 20 20 20 20 18 18 18 16 16 16 16 16 16
tlv_sku_group_search 214210,214211,213910
tlv_diferencias Colour: Black, Reel type: Wrapped coil, Length: 100 m
tlv_dim_product_x 1,000
tlv_dim_product_x_label Width
tlv_dim_product_x_unit mm
tlv_dim_product_y 7
tlv_dim_product_y_label Height
tlv_dim_product_y_unit mm
tlv_dim_product_z 7
tlv_dim_product_z_label Depth
tlv_dim_product_z_unit mm
tlv_weight_product_label Main product weight
tlv_weight_product 0
tlv_weight_product_unit g
tlv_gross_weight_label Gross weight
tlv_gross_weight 43
tlv_gross_weight_unit g
tlv_net_weight_label Net weight
tlv_net_weight_unit g
tlv_net_weight 40
tlv_1_type_pack Reel
tlv_1_type_pcs_pack m
tlv_1_pcs_pack 100
tlv_2_pcs_pack 500
tlv_2_type_pack Box
tlv_2_type_pcs_pack m
tlv_3_pcs_pack 6000
tlv_3_type_pack Pallet
tlv_3_type_pcs_pack m

Mounting details

DETAIL VIEW OF THE COAXIAL CABLE SECTION

A-Inner conductor
B-Dielectric
C-Foil
D-Braid
E- Anti-migrating film
F-Outer sheath

Mounting details

CABLE UNWINDING PROCESS

  1. Place the cable with the label side down
  2. Cut only the plastic from the central hole; keeping the rest intact will prevent the rest of the cable from unwinding
  3. Cut out the zip ties
  4. Pull the cable by the end placed in the center hole
  5. Stack the coil with the label side down to protect the cable