The wishlist name can't be left blank
SK6Fplus 19 VAtC.A coaxial cable Eca Euroclass, A+ Class shielded

SK6Fplus 19 VAtC.A coaxial cable Eca Euroclass, A+ Class shielded

SK6Fplus 19 AtC.A coaxial cable Eca Euroclass, A+ Class shielded

RG-6 coaxial cable with copper-clad steel inner conductor and aluminium braid (CCS/Al), and excellent braid coverage (90%). Triple shielded (TSH) cable, equipped with a second foil for extra shielded. A 19 AtC.A cable with UV-resistant LSFH sheath.

Ref. 414882
Product Sheet
EAN13: 8424450270622
SKU
414882
Highlights
  • Copper-clad steel inner conductor and aluminium braid
  • Class A+ shielded
  • Eca Euroclass

Main features
  • External UV-resistant LSFH sheath, grey colour
  • 75 Ohm characteristic impedance
  • Available in 250m plastic reel

Discover

Class A+ Trishield (TSH) coaxial cable

With three shielding layers (Trishield), this cables provide the highest immunity to interference thanks to its very high shielding. Recommended in cases of high electromagnetic noise levels.

They belong in EN 50117 standard Class A+, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 2.5 mΩ/m
  • For 30 MHz - 1000 MHz => SA > 95 dB
  • For 1000 MHz - 2000 MHz => SA > 85 dB
  • For 2000 MHz - 3000 MHz => SA > 75 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.


ModelSK6Fplus
Cable typeRG-6
StandardEN50117-9-2
EuroclassEca
ClassA+
Inner conductor Diametermm1.02
Inner conductor MaterialCopper-clad steel (CCS)
Inner conductor ResistanceΩ/km < 110
Dielectric Diametermm4.6
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorWhite RAL 9003
Overlapped foilAluminium + Polyester
Braid MaterialAluminium
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)8
Braid Dimensions: strand diameter (Ø)mm0.16
Braid ResistanceΩ/km < 30
Braid Coverage%90
2nd foilYes
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmNo
Outer sheath Diametermm6.8
Outer sheath MaterialLSFH, UV-resistant
Minimum bending radiusmm34
Transfer impedance (5-30MHz)mΩ/m < 2.5
1GHz shieldingdB > 95
Spark TestVac3000
CapacitancepF/m53
ImpedanceΩ75
Velocity ratio%82
Operating temperature°C -30 ... 70
Frequencies
5 MHz47 MHz54 MHz90 MHz200 MHz500 MHz698 MHz800 MHz862 MHz950 MHz1000 MHz1220 MHz1350 MHz1750 MHz2050 MHz2150 MHz2200 MHz2300 MHz2400 MHz3000 MHz
Attenuation (typ.)dB/m
0.02 0.05 0.05 0.06 0.1 0.15 0.17 0.19 0.2 0.21 0.22 0.23 0.25 0.29 0.31 0.32 0.33 0.33 0.34 0.4
Return losses (min.)dB
20 20 20 20 20 18 18 18 18 18 16 16 16 16 15 15 15 15 15 15

Physical data

Net weight: 42 g

Gross weight: 42 g

Width: 7 mm

Height: 7 mm

Depth: 1,000 mm

Main product weight: 42 g

Packing

Reel 250 m

Pallet 7500 m

More Information
tlv_tags

Class A+ Trishield (TSH) coaxial cable

With three shielding layers (Trishield), this cables provide the highest immunity to interference thanks to its very high shielding. Recommended in cases of high electromagnetic noise levels.

They belong in EN 50117 standard Class A+, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 2.5 mΩ/m
  • For 30 MHz - 1000 MHz => SA > 95 dB
  • For 1000 MHz - 2000 MHz => SA > 85 dB
  • For 2000 MHz - 3000 MHz => SA > 75 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.

tlv_reflog SK6LSZHPLUS/250
tlv_tabla_especificaciones
ModelSK6Fplus
Cable typeRG-6
StandardEN50117-9-2
EuroclassEca
ClassA+
Inner conductor Diametermm1.02
Inner conductor MaterialCopper-clad steel (CCS)
Inner conductor ResistanceΩ/km < 110
Dielectric Diametermm4.6
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorWhite RAL 9003
Overlapped foilAluminium + Polyester
Braid MaterialAluminium
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)8
Braid Dimensions: strand diameter (Ø)mm0.16
Braid ResistanceΩ/km < 30
Braid Coverage%90
2nd foilYes
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmNo
Outer sheath Diametermm6.8
Outer sheath MaterialLSFH, UV-resistant
Minimum bending radiusmm34
Transfer impedance (5-30MHz)mΩ/m < 2.5
1GHz shieldingdB > 95
Spark TestVac3000
CapacitancepF/m53
ImpedanceΩ75
Velocity ratio%82
Operating temperature°C -30 ... 70
Frequencies
5 MHz47 MHz54 MHz90 MHz200 MHz500 MHz698 MHz800 MHz862 MHz950 MHz1000 MHz1220 MHz1350 MHz1750 MHz2050 MHz2150 MHz2200 MHz2300 MHz2400 MHz3000 MHz
Attenuation (typ.)dB/m
0.02 0.05 0.05 0.06 0.1 0.15 0.17 0.19 0.2 0.21 0.22 0.23 0.25 0.29 0.31 0.32 0.33 0.33 0.34 0.4
Return losses (min.)dB
20 20 20 20 20 18 18 18 18 18 16 16 16 16 15 15 15 15 15 15
tlv_ean 8424450270622
tlv_dim_product_x 7
tlv_dim_product_x_label Width
tlv_dim_product_x_unit mm
tlv_dim_product_y 7
tlv_dim_product_y_label Height
tlv_dim_product_y_unit mm
tlv_dim_product_z 1,000
tlv_dim_product_z_label Depth
tlv_dim_product_z_unit mm
tlv_weight_product_label Main product weight
tlv_weight_product 42
tlv_weight_product_unit g
tlv_gross_weight_label Gross weight
tlv_gross_weight 42
tlv_gross_weight_unit g
tlv_net_weight_label Net weight
tlv_net_weight_unit g
tlv_net_weight 42
tlv_1_type_pack Reel
tlv_1_type_pcs_pack m
tlv_1_pcs_pack 250
tlv_2_pcs_pack 7500
tlv_2_type_pack Pallet
tlv_2_type_pcs_pack m

Mounting details

DETAIL VIEW OF THE COAXIAL CABLE SECTION

A-Inner conductor
B-Dielectric
C-Foil
D-Braid
E-Second foil