The wishlist name can't be left blank
EasyF 2W Mini-Splitter with UAP 5...2400 MHz 4.5 dB/4.3 dB

EasyF 2W Mini-Splitter with UAP 5...2400 MHz 4.5 dB/4.3 dB

EasyF 4W Splitter with UAP 5...2400 MHz 9 dB/7.5 dB

EasyF 4W Splitter with UAP 5...2400 MHz 9 dB/7.5 dB

EasyF 3W Splitter with UAP 5...2400 MHz 9 dB/8 dB

3-way Splitter with UAP and EasyF connection system for SMATV signals, using a compact design and an efficient electrical behaviour.
The UAP (User Access Point) provides an additional input for the second downcomer, as specified by ICT-2 regulation concerning installations.
Conceived for indoor installation, it can also be used outdoors with a case (ref. 4177).
Supplied in 10-unit boxes.

Ref. 543902
Product Sheet
EAN13: 8424450143759
SKU
543902
Highlights
  • EasyF connection system: easy to install, savings on mounting
  • Made of Zamak, high shielding
  • Outstanding reliability: automated manufacturing using new generation micro-components

Main features
  • Improves through losses
  • Outstanding electrical behaviour: impulsive noise reduction
  • Grounding screw provided
  • DC pass from the outputs to the input

Discover

EasyF connection system: simplicity and savings

EasyF is an innovative connection concept where the inner conductor of the coaxial cable is directly inserted in the device, thus improving connection reliability. Thanks to the absence of F connectors, the chassis can be reduced and the connection of two cables secured with a a single screw.

  • Real time savings: speeding the installation is possible without the need for coaxial cable termination. Furthermore, there is no need for screwing the connectors on the device, which is sometimes difficult when there is little room
  • Connection reliability: the clamp holding the cables prevents the coaxial cable to come off
  • Cost savings: no additional connectors are required (neither F nor IEC)
  • Space optimization: inputs and outputs are always on the same side of the device to prevent coaxial cables from bending, and to make working inside cabinets and register boxes easier
  • Very easy three-step mounting: only screwing and unscrewing the covers is required to connect both cables:

1. Unscrew the device's cover to access the connection

2. Insert the previously stripped coaxial cables

3. Close the cover and screw to ensure connection

Learn more about EasyF system reliability

With EasyF, the connection between the coaxial cable and the device is carried out using an automated system for contact insertion of the inner conductor, without any soldering.

  • Always as new: the device's operating life increases when the factor of solder wearing out with time is removed
  • Failure rate reduction: usually produced as a result of cold soldering joints
  • Electromagnetic behaviour optimization: for high frequencies
  • Our commitment with environment is reinforced: pollution caused by the welding process is eliminated and production power consumption is reduced

Frequency rangeMHz 5 ... 2400
Number of outputs3
Inputs/Bands
TERRSAT
##dB
9 8
Through losses W2dB
9 8
Through losses W3dB
5 4
Rejection between outputsdB
> 15 > 15
Connectors"EasyF" type
Voltage max.V40
Max. currentmA300
DC passOut→In

Physical data

Net weight: 111 g

Gross weight: 170 g

Width: 80 mm

Height: 55 mm

Depth: 14 mm

Main product weight: 111 g

Packing

Box 10 Units

Bucket 40 Units

More Information
tlv_tags

EasyF connection system: simplicity and savings

EasyF is an innovative connection concept where the inner conductor of the coaxial cable is directly inserted in the device, thus improving connection reliability. Thanks to the absence of F connectors, the chassis can be reduced and the connection of two cables secured with a a single screw.

  • Real time savings: speeding the installation is possible without the need for coaxial cable termination. Furthermore, there is no need for screwing the connectors on the device, which is sometimes difficult when there is little room
  • Connection reliability: the clamp holding the cables prevents the coaxial cable to come off
  • Cost savings: no additional connectors are required (neither F nor IEC)
  • Space optimization: inputs and outputs are always on the same side of the device to prevent coaxial cables from bending, and to make working inside cabinets and register boxes easier
  • Very easy three-step mounting: only screwing and unscrewing the covers is required to connect both cables:

1. Unscrew the device's cover to access the connection

2. Insert the previously stripped coaxial cables

3. Close the cover and screw to ensure connection

Learn more about EasyF system reliability

With EasyF, the connection between the coaxial cable and the device is carried out using an automated system for contact insertion of the inner conductor, without any soldering.

  • Always as new: the device's operating life increases when the factor of solder wearing out with time is removed
  • Failure rate reduction: usually produced as a result of cold soldering joints
  • Electromagnetic behaviour optimization: for high frequencies
  • Our commitment with environment is reinforced: pollution caused by the welding process is eliminated and production power consumption is reduced
tlv_caracteristicas_ficha

Sistema de conexión EasyF: sencillez y ahorro

El EasyF se trata un innovador concepto de conexión del conductor interno del cable coaxial (vivo), que se inserta directamente en el dispositivo aumentando la fiabilidad de la conexión. Además gracias a la ausencia de conectores "F", es posible reducir el chasis y securizar la conexión de dos cables con un único tornillo.

  • Ahorro real de tiempo: acelerar la instalación es posible, al no ser necesario realizar la conectorización de los cables coaxiales. Además, se evita el proceso de roscado de los conectores en el dispositivo, que a veces se complica cuando el espacio no es suficiente
  • Fiabilidad de conexión: la brida que sujeta los cables impide que el coaxial se suelte
  • Ahorro económico: no se necesita ningún conector (ni "F" ni "CEI") adicional
  • Optimización del espacio: las entradas y salidas se ubican siempre en el mismo lado del dispositivo, evitando curvar los cables coaxiales y facilitando el trabajo dentro de armarios y registros
  • Montaje muy sencillo en tres pasos: sólo se requiere atornillar y desatornillar las tapas para conectar dos cables:

1. Desatornillar la tapa del repartidor para acceder a la conexión

2. Insertar los cables coaxiales previamente pelados

3. Cerrar la tapa y atornillar para asegurar la conexión

Descubre más acerca de la fiabilidad del sistema EasyF

Con EasyF, la conexión del cable coaxial en el dispositivo se realiza mediante un sistema automatizado de inserción del vivo (conductor interno) por contacto, sin requerir soldadura.

  • Como el primer día: el tiempo de vida del dispositivo de incrementa al eliminar el posible deterioro de las soldaduras con el paso del tiempo
  • Reducción del índice de averías: generalmente producidas por soldaduras frías
  • Optimización del comportamiento electromagnético: en altas frecuencias
  • Refuerzo de nuestro compromiso con el medio ambiente: se elimina la contaminación provocada por el proceso de soldado y se reduce el consumo eléctrico en la producción
tlv_tabla_especificaciones
Frequency rangeMHz 5 ... 2400
Number of outputs3
Inputs/Bands
TERRSAT
##dB
9 8
Through losses W2dB
9 8
Through losses W3dB
5 4
Rejection between outputsdB
> 15 > 15
Connectors"EasyF" type
Voltage max.V40
Max. currentmA300
DC passOut→In
tlv_ean 8424450143759
tlv_dim_product_x 80
tlv_dim_product_x_label Width
tlv_dim_product_x_unit mm
tlv_dim_product_y 55
tlv_dim_product_y_label Height
tlv_dim_product_y_unit mm
tlv_dim_product_z 14
tlv_dim_product_z_label Depth
tlv_dim_product_z_unit mm
tlv_weight_product_label Main product weight
tlv_weight_product 111
tlv_weight_product_unit g
tlv_gross_weight_label Gross weight
tlv_gross_weight 170
tlv_gross_weight_unit g
tlv_net_weight_label Net weight
tlv_net_weight_unit g
tlv_net_weight 111
tlv_1_type_pack Box
tlv_1_type_pcs_pack Units
tlv_1_pcs_pack 10
tlv_2_pcs_pack 40
tlv_2_type_pack Bucket
tlv_2_type_pcs_pack Units

Assembly and advantages of EASYF connection system