The wishlist name can't be left blank
DK6000 data cable F/UTP Cat 6 Dca LSFH 23AWG

DK6000 data cable F/UTP Cat 6 Dca LSFH 23AWG

DK6000 data cable U/UTP Cat 6 Cca LSFH 23AWG

DK6000 data cable U/UTP Cat 6 Cca LSFH 23AWG

DK6000 data cable U/UTP Cat 6 Dca LSFH 24AWG

Category-6 and Dca Euroclass data cable, U/UTP type (Unfoiled), with copper conductor and LSFH sheath (Low Smoke Free of Halogen), white colour (RAL 9010).

Supplied in a 305m dispenser box.

Ref. 212310
Product Sheet
EAN13: 8424450188408
SKU
212310
Highlights
  • U/UTP Unfoiled UTP Cable
  • Solid copper inner conductor (24AWG)
  • Compatible with PoE/PoE+ (Power over Ethernet) technology, allowing the cable to power network devices
  • PE (Polyethylene) copper conductor insulation, 0.92mm diameter
  • LSFH (Low Smoke Free of Halogen) outer sheath, 0.52mm thick and 6.0mm diameter
  • 72% nominal speed
  • Certified by Intertek (ETL Verified Mark)

Discover

Category 6

Data cable category Cat 6 complies with the standard for Gigabit Ethernet and it is backwards compatible, with the standards of the inferior categories (Cat 5/5e and Cat 3). Category 6 evolves over category 5E, allowing to achieve transmission frequencies of up to 250 MHz (in each pair) and 1 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T and 1000BASE-T (Gigabit Ethernet) compliant systems.

Our category 6 cables are characterized:

  • Comply with TIA/EIA-568B.2-1
  • Crucifix type padding
  • Transfer rate up to 1Gbps
  • Frequency range of up to 250 MHz and up to 400MHz in some references
  • Includes rip cord to make it easier to strip the cable
  • Nominal impedance of 100 ohms
  • Maximum resistance per conductor below 9.38 ohms/100m

Compatibility of RJ45 connectors with Televes data cables:

Reference 219602 219701 219901 219910 212201   2123   212302 212305 212310 212101 219302 219312 219313 219322
Female connectors 209901/209907 OK OK OK OK OK OK OK OK OK X X X X X
209905 OK OK OK OK OK OK OK OK OK X X X X X
209921/209925 OK OK OK OK OK OK OK OK OK X X OK OK X
209926 OK OK OK OK OK OK OK OK OK X X OK OK X
209903 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209923 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
209929/209501 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
Male connectors
209902 OK OK OK OK OK OK OK OK OK X X X X X
209961/209962 OK OK OK OK OK OK OK OK OK X X X X X
209904 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209906 OK OK OK OK OK OK OK OK OK X X X X X
209965/209966 OK OK OK OK OK OK OK OK OK X X X X X
209922 OK* OK* OK OK* OK* OK* OK* OK* OK* X X OK OK X
209924 OK* OK* OK OK* OK* OK* OK* OK* OK* OK* OK OK* OK* OK

OK Compatible
OK* Compatible, but there are better choices
X Incompatible
** Mechanical compatibility


ModelDK6000
TypeU/UTP
EuroclassDca
Euroclass: Smoke Productions2
Euroclass: Flaming dropletsd2
Euroclass: Aciditya1
CategorieCat 6
Transmission bandwidth250MHz
Transfer rate1Gbps
Conductor Diametermm0.51
Conductor MaterialSolid copper
Conductor type AWG24
Conductor isolation Diametermm0.92
Conductor isolation MaterialPolyethylene
Crucifix fillerYes
Outer sheath Diametermm6
Outer sheath MaterialLSFH
Outer sheath Thicknessmm0.52
Rip cordYes
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceOhm/100m < 9.38
Nominal speed%72
Working voltageV300
Operating temperature°C -25 ... 70
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31.25 MHz62.5 MHz100 MHz200 MHz250 MHz
Attenuation (max.)dB/100m
2 3.8 5.3 6 7.6 8.5 9.5 10.7 15.4 19.8 29 32.8
Attenuation (typ.)dB/100m
1.9 3.7 5.2 5.8 7.4 8.3 9.2 10.4 14.8 19 27.4 30.7
NEXT (min.)dB/100m
74.3 65.3 60.8 59.3 56.2 54.8 53.3 51.9 47.4 44.3 39.8 38.3
NEXT (typ.)dB/100m
86.8 76.9 73.9 69.8 66.5 64.6 61.8 60.1 54.8 52.3 49 46.3
PS NEXT (min.)dB/100m
72.3 63.3 58.8 57.3 54.2 52.8 51.3 49.9 45.4 42.3 37.8 36.3
PS NEXT (typ.)dB/100m
84.3 74.9 70.9 67 63.5 61.8 59.7 58.3 54.8 50.9 45.3 42.4
ACR-N (min.)dB/100m
72.3 61.5 55.5 53.3 48.6 46.3 43.8 41.2 32 24.5 10.8 5.5
ACR-N (typ.)dB/100m
85 73.3 68 62.6 58.1 54.3 52.1 50 40 34.1 20.6 15.7
PS ACR-N (min.)dB/100m
70.3 59.5 53.5 51.3 46.6 44.3 41.8 39.2 30 22.5 8.8 3.5
PS ACR-N (typ.)dB/100m
82.4 71.3 64.7 60.1 55.1 52.4 50.6 47.2 39 31 18.6 13.7
ACR-F (min.)dB/100m
67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 21.8 19.8
ACR-F (typ.)dB/100m
75.3 62.5 56.9 55.1 52.2 51.3 53.6 47.9 40.9 37.3 30.9 27.9
PS ACR-F (min.)dB/100m
64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 18.8 16.8
PS ACR-F (typ.)dB/100m
73.4 60.7 55 53.4 51.1 49.9 46.3 44.1 39.9 31.7 25.7 24.6
Return losses (min.)dB
20 23 24.5 25 25 25 24.3 30.6 21.5 20.1 18 17.3
Return lossesdB
25 26.1 28.4 28.3 29.5 28.1 29 24.5 29.4 26 23.2 22

Physical data

Net weight: 34 g

Gross weight: 37 g

Width: 6 mm

Height: 1,000 mm

Depth: 6 mm

Main product weight: 34 g

Packing

Box 305 m

Pallet 7320 m

More Information
tlv_tags

Category 6

Data cable category Cat 6 complies with the standard for Gigabit Ethernet and it is backwards compatible, with the standards of the inferior categories (Cat 5/5e and Cat 3). Category 6 evolves over category 5E, allowing to achieve transmission frequencies of up to 250 MHz (in each pair) and 1 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T and 1000BASE-T (Gigabit Ethernet) compliant systems.

Our category 6 cables are characterized:

  • Comply with TIA/EIA-568B.2-1
  • Crucifix type padding
  • Transfer rate up to 1Gbps
  • Frequency range of up to 250 MHz and up to 400MHz in some references
  • Includes rip cord to make it easier to strip the cable
  • Nominal impedance of 100 ohms
  • Maximum resistance per conductor below 9.38 ohms/100m

Compatibility of RJ45 connectors with Televes data cables:

Reference 219602 219701 219901 219910 212201   2123   212302 212305 212310 212101 219302 219312 219313 219322
Female connectors 209901/209907 OK OK OK OK OK OK OK OK OK X X X X X
209905 OK OK OK OK OK OK OK OK OK X X X X X
209921/209925 OK OK OK OK OK OK OK OK OK X X OK OK X
209926 OK OK OK OK OK OK OK OK OK X X OK OK X
209903 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209923 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
209929/209501 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
Male connectors
209902 OK OK OK OK OK OK OK OK OK X X X X X
209961/209962 OK OK OK OK OK OK OK OK OK X X X X X
209904 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209906 OK OK OK OK OK OK OK OK OK X X X X X
209965/209966 OK OK OK OK OK OK OK OK OK X X X X X
209922 OK* OK* OK OK* OK* OK* OK* OK* OK* X X OK OK X
209924 OK* OK* OK OK* OK* OK* OK* OK* OK* OK* OK OK* OK* OK

OK Compatible
OK* Compatible, but there are better choices
X Incompatible
** Mechanical compatibility

tlv_reflog CAT6L305V
tlv_tabla_especificaciones
ModelDK6000
TypeU/UTP
EuroclassDca
Euroclass: Smoke Productions2
Euroclass: Flaming dropletsd2
Euroclass: Aciditya1
CategorieCat 6
Transmission bandwidth250MHz
Transfer rate1Gbps
Conductor Diametermm0.51
Conductor MaterialSolid copper
Conductor type AWG24
Conductor isolation Diametermm0.92
Conductor isolation MaterialPolyethylene
Crucifix fillerYes
Outer sheath Diametermm6
Outer sheath MaterialLSFH
Outer sheath Thicknessmm0.52
Rip cordYes
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceOhm/100m < 9.38
Nominal speed%72
Working voltageV300
Operating temperature°C -25 ... 70
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31.25 MHz62.5 MHz100 MHz200 MHz250 MHz
Attenuation (max.)dB/100m
2 3.8 5.3 6 7.6 8.5 9.5 10.7 15.4 19.8 29 32.8
Attenuation (typ.)dB/100m
1.9 3.7 5.2 5.8 7.4 8.3 9.2 10.4 14.8 19 27.4 30.7
NEXT (min.)dB/100m
74.3 65.3 60.8 59.3 56.2 54.8 53.3 51.9 47.4 44.3 39.8 38.3
NEXT (typ.)dB/100m
86.8 76.9 73.9 69.8 66.5 64.6 61.8 60.1 54.8 52.3 49 46.3
PS NEXT (min.)dB/100m
72.3 63.3 58.8 57.3 54.2 52.8 51.3 49.9 45.4 42.3 37.8 36.3
PS NEXT (typ.)dB/100m
84.3 74.9 70.9 67 63.5 61.8 59.7 58.3 54.8 50.9 45.3 42.4
ACR-N (min.)dB/100m
72.3 61.5 55.5 53.3 48.6 46.3 43.8 41.2 32 24.5 10.8 5.5
ACR-N (typ.)dB/100m
85 73.3 68 62.6 58.1 54.3 52.1 50 40 34.1 20.6 15.7
PS ACR-N (min.)dB/100m
70.3 59.5 53.5 51.3 46.6 44.3 41.8 39.2 30 22.5 8.8 3.5
PS ACR-N (typ.)dB/100m
82.4 71.3 64.7 60.1 55.1 52.4 50.6 47.2 39 31 18.6 13.7
ACR-F (min.)dB/100m
67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 21.8 19.8
ACR-F (typ.)dB/100m
75.3 62.5 56.9 55.1 52.2 51.3 53.6 47.9 40.9 37.3 30.9 27.9
PS ACR-F (min.)dB/100m
64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 18.8 16.8
PS ACR-F (typ.)dB/100m
73.4 60.7 55 53.4 51.1 49.9 46.3 44.1 39.9 31.7 25.7 24.6
Return losses (min.)dB
20 23 24.5 25 25 25 24.3 30.6 21.5 20.1 18 17.3
Return lossesdB
25 26.1 28.4 28.3 29.5 28.1 29 24.5 29.4 26 23.2 22
tlv_ean 8424450188408
tlv_dim_product_x 6
tlv_dim_product_x_label Width
tlv_dim_product_x_unit mm
tlv_dim_product_y 1,000
tlv_dim_product_y_label Height
tlv_dim_product_y_unit mm
tlv_dim_product_z 6
tlv_dim_product_z_label Depth
tlv_dim_product_z_unit mm
tlv_weight_product_label Main product weight
tlv_weight_product 34
tlv_weight_product_unit g
tlv_gross_weight_label Gross weight
tlv_gross_weight 37
tlv_gross_weight_unit g
tlv_net_weight_label Net weight
tlv_net_weight_unit g
tlv_net_weight 34
tlv_1_type_pack Box
tlv_1_type_pcs_pack m
tlv_1_pcs_pack 305
tlv_2_pcs_pack 7320
tlv_2_type_pack Pallet
tlv_2_type_pcs_pack m

Mounting details

DETAIL VIEW OF THE DATA CABLE SECTION

  1. Inner conductor
  2. Inner conductor isolation
  3. Crucifix Filler
  4. Outer sheath
  5. Rip cord

Comparison between two connectorisation techniques of a data cable with a female connector

How to install a female RJ45 data connector using a professional tool

How to install a female RJ45 data connector manually