The wishlist name can't be left blank

CXT 19 AtC coaxial cable Dca Euroclass, A Class shielded

RG-6 coaxial cable with copper inner conductor and aluminium braid (Cu/Al), and an excellent braid coverage (79%). A 19 AtC cable with double shielded and LSFH sheath.

Ref. 212811
EAN13: 8424450169834
Highlights
  • Copper inner conductor and aluminium braid
  • Class A shielded
  • Dca-s2,d2,a1 Euroclass

Main features
  • Grey-colour external LSFH sheath
  • 75 Ohm characteristic impedance
  • 250 m wood reel

Discover

Double-shielded Class A coaxial cable

With 2 shielding layers, these cables provide an outstanding shielding thanks to a high-coverage braid.

They belong in EN 50117 standard Class A, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 5 mΩ/m
  • For 30 MHz - 1000 MHz => SA > 85 dB
  • For 1000 MHz - 2000 MHz => SA > 75 dB
  • For 2000 MHz - 3000 MHz => SA > 65 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.


ModelCXT
Cable typeRG-6
StandardEN 50117-9-2
EuroclassDca
Euroclass: Smoke Productions2
Euroclass: Flaming dropletsd2
Euroclass: Aciditya1
ClassA
Inner conductor Diametermm1
Inner conductor MaterialCopper (Cu)
Inner conductor ResistanceOhm/km < 23
Dielectric Diametermm4.5
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorWhite RAL 9003
Overlapped foilAluminium + Polyester
Braid MaterialAluminium
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)8
Braid Dimensions: strand diameter (Ø)mm0.12
Braid ResistanceOhm/km < 31
Braid Coverage%79
2nd foilNo
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmNo
Outer sheath Diametermm6.5
Outer sheath MaterialLSFH
Minimum bending radiusmm32.5
Transfer impedance (5-30MHz)mΩ /m < 5
1GHz shieldingdB > 85
Spark TestVac3000
CapacitancepF/m54
ImpedanceΩ75
Velocity ratio%82
Operating temperature°C -25 ... 70
Atenuacion 5MHzdB/m0.01
Atenuacion 47MHzdB/m0.04
Atenuacion 54MHzdB/m0.05
Atenuacion 90MHzdB/m0.06
Atenuacion 200MHzdB/m0.09
Atenuacion 500MHzdB/m0.14
Atenuacion 698MHzdB/m0.17
Atenuacion 800MHzdB/m0.19
Atenuacion 862MHzdB/m0.19
Atenuacion 950MHzdB/m0.2
Atenuacion 1000MHzdB/m0.21
Atenuacion 1220MHzdB/m0.23
Atenuacion 1350MHzdB/m0.25
Atenuacion 1750MHzdB/m0.29
Atenuacion 2050MHzdB/m0.32
Atenuacion 2150MHzdB/m0.33
Atenuacion 2200MHzdB/m0.35
Atenuacion 2300MHzdB/m0.35
Atenuacion 2400MHzdB/m0.35
Atenuacion 3000MHzdB/m0.39
Return losses 5MHzdB20
Return losses 47MHzdB20
Return losses 54MHzdB20
Return losses 90MHzdB20
Return losses 200MHzdB20
Return losses 500MHzdB18
Return losses 698MHzdB18
Return losses 800MHzdB18
Return losses 862MHzdB18
Return losses 950MHzdB18
Return losses 1000MHzdB18
Return losses 1220MHzdB16
Return losses 1350MHzdB16
Return losses 1750MHzdB16
Return losses 2050MHzdB15
Return losses 2150MHzdB15
Return losses 2200MHzdB15
Return losses 2300MHzdB15
Return losses 2400MHzdB15
Return losses 3000MHzdB15

Physical data

Net weight: 40 g

Gross weight: 40 g

Width: 6 mm

Height: 1,000 mm

Depth: 6 mm

Main product weight: 39 g

Packing

Reel 250 m

Pallet 7500 m

Pallet 9000 m

More Information
tlv_tags

Double-shielded Class A coaxial cable

With 2 shielding layers, these cables provide an outstanding shielding thanks to a high-coverage braid.

They belong in EN 50117 standard Class A, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 5 mΩ/m
  • For 30 MHz - 1000 MHz => SA > 85 dB
  • For 1000 MHz - 2000 MHz => SA > 75 dB
  • For 2000 MHz - 3000 MHz => SA > 65 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.

tlv_caracteristicas_ficha

Double-shielded Class A coaxial cable

With 2 shielding layers, these cables provide an outstanding shielding thanks to a high-coverage braid.

They belong in EN 50117 standard Class A, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 5 mΩ/m
  • For 5 MHz - 1000 MHz => SA > 85 dB
  • For 1000 MHz - 2000 MHz => SA > 75 dB
  • For 2000 MHz - 3000 MHz => SA > 65 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.

tlv_tabla_especificaciones
ModelCXT
Cable typeRG-6
StandardEN 50117-9-2
EuroclassDca
Euroclass: Smoke Productions2
Euroclass: Flaming dropletsd2
Euroclass: Aciditya1
ClassA
Inner conductor Diametermm1
Inner conductor MaterialCopper (Cu)
Inner conductor ResistanceOhm/km < 23
Dielectric Diametermm4.5
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorWhite RAL 9003
Overlapped foilAluminium + Polyester
Braid MaterialAluminium
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)8
Braid Dimensions: strand diameter (Ø)mm0.12
Braid ResistanceOhm/km < 31
Braid Coverage%79
2nd foilNo
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmNo
Outer sheath Diametermm6.5
Outer sheath MaterialLSFH
Minimum bending radiusmm32.5
Transfer impedance (5-30MHz)mΩ /m < 5
1GHz shieldingdB > 85
Spark TestVac3000
CapacitancepF/m54
ImpedanceΩ75
Velocity ratio%82
Operating temperature°C -25 ... 70
Atenuacion 5MHzdB/m0.01
Atenuacion 47MHzdB/m0.04
Atenuacion 54MHzdB/m0.05
Atenuacion 90MHzdB/m0.06
Atenuacion 200MHzdB/m0.09
Atenuacion 500MHzdB/m0.14
Atenuacion 698MHzdB/m0.17
Atenuacion 800MHzdB/m0.19
Atenuacion 862MHzdB/m0.19
Atenuacion 950MHzdB/m0.2
Atenuacion 1000MHzdB/m0.21
Atenuacion 1220MHzdB/m0.23
Atenuacion 1350MHzdB/m0.25
Atenuacion 1750MHzdB/m0.29
Atenuacion 2050MHzdB/m0.32
Atenuacion 2150MHzdB/m0.33
Atenuacion 2200MHzdB/m0.35
Atenuacion 2300MHzdB/m0.35
Atenuacion 2400MHzdB/m0.35
Atenuacion 3000MHzdB/m0.39
Return losses 5MHzdB20
Return losses 47MHzdB20
Return losses 54MHzdB20
Return losses 90MHzdB20
Return losses 200MHzdB20
Return losses 500MHzdB18
Return losses 698MHzdB18
Return losses 800MHzdB18
Return losses 862MHzdB18
Return losses 950MHzdB18
Return losses 1000MHzdB18
Return losses 1220MHzdB16
Return losses 1350MHzdB16
Return losses 1750MHzdB16
Return losses 2050MHzdB15
Return losses 2150MHzdB15
Return losses 2200MHzdB15
Return losses 2300MHzdB15
Return losses 2400MHzdB15
Return losses 3000MHzdB15
tlv_ean 8424450169834
tlv_dim_product_x 6
tlv_dim_product_x_label Width
tlv_dim_product_x_unit mm
tlv_dim_product_y 1,000
tlv_dim_product_y_label Height
tlv_dim_product_y_unit mm
tlv_dim_product_z 6
tlv_dim_product_z_label Depth
tlv_dim_product_z_unit mm
tlv_weight_product_label Main product weight
tlv_weight_product 39
tlv_weight_product_unit g
tlv_gross_weight_label Gross weight
tlv_gross_weight 40
tlv_gross_weight_unit g
tlv_net_weight_label Net weight
tlv_net_weight_unit g
tlv_net_weight 40
tlv_1_type_pack Reel
tlv_1_type_pcs_pack m
tlv_1_pcs_pack 250
tlv_2_pcs_pack 7500
tlv_2_type_pack Pallet
tlv_2_type_pcs_pack m
tlv_3_pcs_pack 9000
tlv_3_type_pack Pallet
tlv_3_type_pcs_pack m

Mounting details

DETAIL VIEW OF THE COAXIAL CABLE SECTION

A-Inner conductor
B-Dielectric
C-Foil
D-Braid
E-Outer sheath

Cookies use

We use our own cookies and those of third parties to analyze the use and metrics of our web. You can change settings, accept or reject the use of cookies by clicking on the next button.

For more information, click on our Cookies Policy.