The wishlist name can't be left blank
MiniKom EasyF broadband multiband amplifier 4 inputs: FM-VHF-UHF-SAT

MiniKom EasyF broadband multiband amplifier 4 inputs: FM-VHF-UHF-SAT

MiniKom EasyF broadband multiband amplifier 5 inputs: FM-VHF-UHF-UHF-SAT

Configurable headend multiband amplifier for SMATV systems with separate amplification that guarantees the absence of intermodulation among inputs.
Equipped with 5 inputs: FM-VHF-UHF-UHF-SAT; the VHF and UHF inputs have both selectable gain margins, whereas the FM input has a single amplifying stage. The SAT stage includes a switch for LNB powering selection, either local mode (through the power supply itself) or remote mode (through an external STB).
Equipped with LTE700 filtering and an output LED signal indicator for immediate network failure detection.

Ref. 562221
EAN13: 8424450228487
Highlights
  • Very compact size (103 mm x 103 mm x 50 mm)
  • LED indicators to display the presence of both output signal and power supply
  • Switched configurable gain (high/low), and high output level
  • Two amplifying stages for TV bands
  • Switch-mode power supply ensuring low power consumption
  • EasyF connection system
  • High-screening Zamak chassis

Main features
  • Test output (-30 dB)
  • Intuitive front cover, including adjustments and block diagram
  • Power selection switch for LNB: local or remote
  • ON/OFF DC pass switch on VHF and UHF inputs for pre-amplifier or BOSS system powering
  • Can be wall-mounted using screws

Discover

EasyF connection system: simplicity and savings

EasyF is an innovative connection concept where the inner conductor of the coaxial cable is directly inserted in the device, thus improving connection reliability. Thanks to the absence of F connectors, the chassis can be reduced and the connection of two cables secured with a a single screw.

  • Real time savings: speeding the installation is possible without the need for coaxial cable termination. Furthermore, there is no need for screwing the connectors on the device, which is sometimes difficult when there is little room
  • Connection reliability: the clamp holding the cables prevents the coaxial cable to come off
  • Cost savings: no additional connectors are required (neither F nor IEC)
  • Space optimization: inputs and outputs are always on the same side of the device to prevent coaxial cables from bending, and to make working inside cabinets and register boxes easier
  • Very easy three-step mounting: only screwing and unscrewing the covers is required to connect both cables:

1. Unscrew the device's cover to access the connection

2. Insert the previously stripped coaxial cables

3. Close the cover and screw to ensure connection

Learn more about EasyF system reliability

With EasyF, the connection between the coaxial cable and the device is carried out using an automated system for contact insertion of the inner conductor, without any soldering.

  • Always as new: the device's operating life increases when the factor of solder wearing out with time is removed
  • Failure rate reduction: usually produced as a result of cold soldering joints
  • Electromagnetic behaviour optimization: for high frequencies
  • Our commitment with environment is reinforced: pollution caused by the welding process is eliminated and production power consumption is reduced

Bands
FMVHFUHF 1UHF 2SAT
Frequency rangeMHz
88 ... 108174 ... 400470 ... 694470 ... 694950 ... 2150
High gaindB
15 34 36 36 42
Low gaindB
15 24 26 26 42
Gain adjustment rangedB
0 ... 200 ... 200 ... 200 ... 200 ... 30
Noise figuredB
6 5 10 10 --
Output level EN50083 IMD3 2tones -60dBdBµV
120 121 122 122 122
Output level DIN45004BdBµV
113 114 115 115 --
Output level EN50083 IMD3 2tones -60dBdBµV
110 111 112 112 --
Output level EN50083 IMD2 2tones -60dBdBµV
--101 ------
EqualizatordB
--------0 ... 15
Powering per inputsVdc
0 12 12 0 --
Max current inputmA
0 200 200 0 --
Max. local current for LNBmA
--------400
Powering LNB - LocalVdc
--------12
Max. remote current for LNBmA
--------500
Powering LNB - RemoteVdc
--------12
Max. power consumptionW12.5
Current consumptionmA120
Max power consumption (Inputr powering OFF)W6.5
Max power consumption (Inputs powering ON)W12.5
Input voltageVac 220 ... 230
Mains frequency50 Hz / 60 Hz
Number of inputs5
Number of outputs1
Connectors"EasyF" type
Protection index (IP)20
Operating temperature°C -5 ... 45

Physical data

Net weight: 637 g

Gross weight: 707 g

Width: 103 mm

Height: 103 mm

Depth: 50 mm

Main product weight: 637 g

Packing

Box 1 Units

More Information
tlv_tags

EasyF connection system: simplicity and savings

EasyF is an innovative connection concept where the inner conductor of the coaxial cable is directly inserted in the device, thus improving connection reliability. Thanks to the absence of F connectors, the chassis can be reduced and the connection of two cables secured with a a single screw.

  • Real time savings: speeding the installation is possible without the need for coaxial cable termination. Furthermore, there is no need for screwing the connectors on the device, which is sometimes difficult when there is little room
  • Connection reliability: the clamp holding the cables prevents the coaxial cable to come off
  • Cost savings: no additional connectors are required (neither F nor IEC)
  • Space optimization: inputs and outputs are always on the same side of the device to prevent coaxial cables from bending, and to make working inside cabinets and register boxes easier
  • Very easy three-step mounting: only screwing and unscrewing the covers is required to connect both cables:

1. Unscrew the device's cover to access the connection

2. Insert the previously stripped coaxial cables

3. Close the cover and screw to ensure connection

Learn more about EasyF system reliability

With EasyF, the connection between the coaxial cable and the device is carried out using an automated system for contact insertion of the inner conductor, without any soldering.

  • Always as new: the device's operating life increases when the factor of solder wearing out with time is removed
  • Failure rate reduction: usually produced as a result of cold soldering joints
  • Electromagnetic behaviour optimization: for high frequencies
  • Our commitment with environment is reinforced: pollution caused by the welding process is eliminated and production power consumption is reduced
tlv_reflog MVNSF536DD2
tlv_tabla_especificaciones
Bands
FMVHFUHF 1UHF 2SAT
Frequency rangeMHz
88 ... 108174 ... 400470 ... 694470 ... 694950 ... 2150
High gaindB
15 34 36 36 42
Low gaindB
15 24 26 26 42
Gain adjustment rangedB
0 ... 200 ... 200 ... 200 ... 200 ... 30
Noise figuredB
6 5 10 10 --
Output level EN50083 IMD3 2tones -60dBdBµV
120 121 122 122 122
Output level DIN45004BdBµV
113 114 115 115 --
Output level EN50083 IMD3 2tones -60dBdBµV
110 111 112 112 --
Output level EN50083 IMD2 2tones -60dBdBµV
--101 ------
EqualizatordB
--------0 ... 15
Powering per inputsVdc
0 12 12 0 --
Max current inputmA
0 200 200 0 --
Max. local current for LNBmA
--------400
Powering LNB - LocalVdc
--------12
Max. remote current for LNBmA
--------500
Powering LNB - RemoteVdc
--------12
Max. power consumptionW12.5
Current consumptionmA120
Max power consumption (Inputr powering OFF)W6.5
Max power consumption (Inputs powering ON)W12.5
Input voltageVac 220 ... 230
Mains frequency50 Hz / 60 Hz
Number of inputs5
Number of outputs1
Connectors"EasyF" type
Protection index (IP)20
Operating temperature°C -5 ... 45
tlv_ean 8424450228487
tlv_dim_product_x 103
tlv_dim_product_x_label Width
tlv_dim_product_x_unit mm
tlv_dim_product_y 103
tlv_dim_product_y_label Height
tlv_dim_product_y_unit mm
tlv_dim_product_z 50
tlv_dim_product_z_label Depth
tlv_dim_product_z_unit mm
tlv_weight_product_label Main product weight
tlv_weight_product 637
tlv_weight_product_unit g
tlv_gross_weight_label Gross weight
tlv_gross_weight 707
tlv_gross_weight_unit g
tlv_net_weight_label Net weight
tlv_net_weight_unit g
tlv_net_weight 637
tlv_1_type_pack Box
tlv_1_type_pcs_pack Units
tlv_1_pcs_pack 1

Assembly and advantages of EASYF connection system

Cookies use

We use our own cookies and those of third parties to analyze the use and metrics of our web. You can change settings, accept or reject the use of cookies by clicking on the next button.

For more information, click on our Cookies Policy.