The wishlist name can't be left blank

DK7000 data cable S/FTP Cat 7 Cca LSFH 23AWG

Category-7 and Cca Euroclass data cable, S/FTP type (Foiled pairs and foiled cable), with copper conductor and LSFH sheath (Low Smoke Free of Halogen), white colour (RAL 9010).
It achieves a bandwidth up to 1000 MHz (higher than the 600 MHz specified by the standard).
Supplied in a wood reel.
Ref. 219102
Product Sheet
EAN13: 8424450253069
SKU
219102
Highlights
  • S/FTP Foiled FTP Cable (foiled pairs)
  • Solid copper inner conductor (23AWG)
  • Compatible with PoE/PoE+ (Power over Ethernet) technology, allowing the cable to power network devices
  • PE (Polyethylene) copper conductor insulation, 1.30mm diameter
  • Aluminium+polyester shielding foil
  • Tinned copper outer shielding braid
  • LSFH (Low Smoke Free of Halogen) outer sheath, 0.70mm thick and 7.4mm diameter
  • 79% nominal speed
  • Certified according to the applicable standards as defined in the available declarations of conformity and performance

Discover

Category 7

Data cable category Cat 7 complies with the standard for 10 Gigabit Ethernet and it is backwards compatible, with the standards of the inferior categories (Cat 6A/6/5e and Cat 3). Category 7 evolves over category 6A, allowing to achieve transmission frequencies of up to 600 MHz (in each pair) and 10 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T, 1000BASE-T and 10GBASE-T compliant systems.

Our category 7 cables are characterized for:

  • Comply with: EN 50173-1:2011, ISO/IEC 11801-1:2017, IEC 61156-5:2009, EN 50288-4-1:2013, EN 50288-4-2:2013
  • Transfer rate up to 10Gbps
  • Frequency range of up to 1000 MHz (higher than the 600 MHz specified by the standard)
  • Nominal impedance of 100 ohms
  • Maximum resistance per conductor below 93,8 ohms/Km

Compatibility of RJ45 connectors with Televes data cables:

Reference 219602 219701 219901 219910 212201   2123   212302 212305 212310 212101 219302 219312 219313 219322
Female connectors 209901/209907 OK OK OK OK OK OK OK OK OK X X X X X
209905 OK OK OK OK OK OK OK OK OK X X X X X
209921/209925 OK OK OK OK OK OK OK OK OK X X OK OK X
209926 OK OK OK OK OK OK OK OK OK X X OK OK X
209903 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209923 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
209929/209501 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
Male connectors
209902 OK OK OK OK OK OK OK OK OK X X X X X
209961/209962 OK OK OK OK OK OK OK OK OK X X X X X
209904 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209906 OK OK OK OK OK OK OK OK OK X X X X X
209965/209966 OK OK OK OK OK OK OK OK OK X X X X X
209922 OK* OK* OK OK* OK* OK* OK* OK* OK* X X OK OK X
209924 OK* OK* OK OK* OK* OK* OK* OK* OK* OK* OK OK* OK* OK

OK Compatible
OK* Compatible, but there are better choices
X Incompatible
** Mechanical compatibility


ModelDK7000
TypeS/FTP
EuroclassCca
Euroclass: Smoke Productions1a
Euroclass: Flaming dropletsd1
Euroclass: Aciditya1
CategorieCat 7
Transmission bandwidth1000MHz
Transfer rate10Gbps
Conductor Diametermm0.55
Conductor MaterialSolid copper
Conductor type AWG23
Copper weightkg/km18.35
Conductor isolation Diametermm1.3
Conductor isolation MaterialPolyethylene
Crucifix fillerNo
Shielding foil of pairsAluminium + Polyester
Outer shielding braidTinned copper (CuSn)
Outer sheath Diametermm7.4
Outer sheath MaterialLSFH
Outer sheath Thicknessmm0.7
Rip cordNo
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceOhm/100m < 9.38
Nominal speed%79
Working voltageV125
Operating temperature°C -25 ... 70
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31.25 MHz62.5 MHz100 MHz200 MHz250 MHz300 MHz400 MHz500 MHz600 MHz800 MHz1000 MHz
Attenuation (max.)dB/100m
4 ------8.1 --------20.8 --33.8 ----49.3 54.6 ----
Attenuation (typ.)dB/100m
2 3.8 5.1 5.7 7.3 8.2 9.2 10.4 14.9 18.9 27 30.3 33.3 38.6 43.5 48.1 59.6 63.9
NEXT (min.)dB/100m
65 ------65 --------62.9 --56.9 ----52.4 51.2 ----
NEXT (typ.)dB/100m
85.7 92.2 90.6 93.9 90.1 92.1 87.8 86.3 81.2 77.8 71.1 69.3 68.9 66.7 64.9 62.5 62.6 58.6
PS NEXT (min.)dB/100m
62 ------62 --------59.9 --53.9 ----49.4 48.2 ----
PS NEXT (typ.)dB/100m
84.2 89.1 87.9 91.5 88 89.5 86.8 84.8 80.4 77.2 69.9 68.4 68.1 65.8 64.5 62.1 59.8 58.5
ACR-N (min.)dB/100m
61 ------56.9 --------42.1 --23.1 ----3.1 -3.4 ----
ACR-N (typ.)dB/100m
83.6 88.4 85.4 88.1 82.8 83.9 78.5 75.8 66.1 58.7 43.8 38.6 35.2 27.5 20.8 14 3 -5.2
PS ACR-N (min.)dB/100m
58 ------53.9 --------39.1 --20.1 ----0.1 -6.4 ----
PS ACR-N (typ.)dB/100m
82.2 85.3 82.8 85.8 80.7 81.2 77.5 74.3 65.3 58.1 42.6 37.7 34.4 26.7 20.3 13.5 0.2 -5.4
ACR-F (min.)dB/100m
65 ------57.5 --------44.4 --37.8 ----32.6 31.3 ----
ACR-F (typ.)dB/100m
83 86.9 87.6 87.7 84.7 83.3 83 81.1 78.2 74.8 65.2 63 66.3 59.5 54.1 53.8 42.8 34.6
PS ACR-F (min.)dB/100m
62 ------54.5 --------41.4 --34.8 ----29.6 28.3 ----
PS ACR-F (typ.)dB/100m
82 85 86.3 86.1 83.5 81.8 81.2 79 75.9 73.3 64.6 61.8 64 57.5 52.7 51.4 41 32.3
Return losses (min.)dB
21 ------20 --------14 --10 ----10 10 ----
Return lossesdB
25.5 28.5 30.7 32 33.1 36.9 33.1 34.1 34.6 33 29.7 28.5 26.9 24.9 22.2 21.7 18.4 14.9

Physical data

Net weight: 54 g

Gross weight: 59 g

Width: 7 mm

Height: 1,000 mm

Depth: 7 mm

Main product weight: 54 g

Packing

Reel 500 m

More Information
tlv_tags

Category 7

Data cable category Cat 7 complies with the standard for 10 Gigabit Ethernet and it is backwards compatible, with the standards of the inferior categories (Cat 6A/6/5e and Cat 3). Category 7 evolves over category 6A, allowing to achieve transmission frequencies of up to 600 MHz (in each pair) and 10 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T, 1000BASE-T and 10GBASE-T compliant systems.

Our category 7 cables are characterized for:

  • Comply with: EN 50173-1:2011, ISO/IEC 11801-1:2017, IEC 61156-5:2009, EN 50288-4-1:2013, EN 50288-4-2:2013
  • Transfer rate up to 10Gbps
  • Frequency range of up to 1000 MHz (higher than the 600 MHz specified by the standard)
  • Nominal impedance of 100 ohms
  • Maximum resistance per conductor below 93,8 ohms/Km

Compatibility of RJ45 connectors with Televes data cables:

Reference 219602 219701 219901 219910 212201   2123   212302 212305 212310 212101 219302 219312 219313 219322
Female connectors 209901/209907 OK OK OK OK OK OK OK OK OK X X X X X
209905 OK OK OK OK OK OK OK OK OK X X X X X
209921/209925 OK OK OK OK OK OK OK OK OK X X OK OK X
209926 OK OK OK OK OK OK OK OK OK X X OK OK X
209903 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209923 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
209929/209501 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
Male connectors
209902 OK OK OK OK OK OK OK OK OK X X X X X
209961/209962 OK OK OK OK OK OK OK OK OK X X X X X
209904 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209906 OK OK OK OK OK OK OK OK OK X X X X X
209965/209966 OK OK OK OK OK OK OK OK OK X X X X X
209922 OK* OK* OK OK* OK* OK* OK* OK* OK* X X OK OK X
209924 OK* OK* OK OK* OK* OK* OK* OK* OK* OK* OK OK* OK* OK

OK Compatible
OK* Compatible, but there are better choices
X Incompatible
** Mechanical compatibility

tlv_reflog CAT7L500W
tlv_tabla_especificaciones
ModelDK7000
TypeS/FTP
EuroclassCca
Euroclass: Smoke Productions1a
Euroclass: Flaming dropletsd1
Euroclass: Aciditya1
CategorieCat 7
Transmission bandwidth1000MHz
Transfer rate10Gbps
Conductor Diametermm0.55
Conductor MaterialSolid copper
Conductor type AWG23
Copper weightkg/km18.35
Conductor isolation Diametermm1.3
Conductor isolation MaterialPolyethylene
Crucifix fillerNo
Shielding foil of pairsAluminium + Polyester
Outer shielding braidTinned copper (CuSn)
Outer sheath Diametermm7.4
Outer sheath MaterialLSFH
Outer sheath Thicknessmm0.7
Rip cordNo
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceOhm/100m < 9.38
Nominal speed%79
Working voltageV125
Operating temperature°C -25 ... 70
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31.25 MHz62.5 MHz100 MHz200 MHz250 MHz300 MHz400 MHz500 MHz600 MHz800 MHz1000 MHz
Attenuation (max.)dB/100m
4 ------8.1 --------20.8 --33.8 ----49.3 54.6 ----
Attenuation (typ.)dB/100m
2 3.8 5.1 5.7 7.3 8.2 9.2 10.4 14.9 18.9 27 30.3 33.3 38.6 43.5 48.1 59.6 63.9
NEXT (min.)dB/100m
65 ------65 --------62.9 --56.9 ----52.4 51.2 ----
NEXT (typ.)dB/100m
85.7 92.2 90.6 93.9 90.1 92.1 87.8 86.3 81.2 77.8 71.1 69.3 68.9 66.7 64.9 62.5 62.6 58.6
PS NEXT (min.)dB/100m
62 ------62 --------59.9 --53.9 ----49.4 48.2 ----
PS NEXT (typ.)dB/100m
84.2 89.1 87.9 91.5 88 89.5 86.8 84.8 80.4 77.2 69.9 68.4 68.1 65.8 64.5 62.1 59.8 58.5
ACR-N (min.)dB/100m
61 ------56.9 --------42.1 --23.1 ----3.1 -3.4 ----
ACR-N (typ.)dB/100m
83.6 88.4 85.4 88.1 82.8 83.9 78.5 75.8 66.1 58.7 43.8 38.6 35.2 27.5 20.8 14 3 -5.2
PS ACR-N (min.)dB/100m
58 ------53.9 --------39.1 --20.1 ----0.1 -6.4 ----
PS ACR-N (typ.)dB/100m
82.2 85.3 82.8 85.8 80.7 81.2 77.5 74.3 65.3 58.1 42.6 37.7 34.4 26.7 20.3 13.5 0.2 -5.4
ACR-F (min.)dB/100m
65 ------57.5 --------44.4 --37.8 ----32.6 31.3 ----
ACR-F (typ.)dB/100m
83 86.9 87.6 87.7 84.7 83.3 83 81.1 78.2 74.8 65.2 63 66.3 59.5 54.1 53.8 42.8 34.6
PS ACR-F (min.)dB/100m
62 ------54.5 --------41.4 --34.8 ----29.6 28.3 ----
PS ACR-F (typ.)dB/100m
82 85 86.3 86.1 83.5 81.8 81.2 79 75.9 73.3 64.6 61.8 64 57.5 52.7 51.4 41 32.3
Return losses (min.)dB
21 ------20 --------14 --10 ----10 10 ----
Return lossesdB
25.5 28.5 30.7 32 33.1 36.9 33.1 34.1 34.6 33 29.7 28.5 26.9 24.9 22.2 21.7 18.4 14.9
tlv_diferencias 500m
tlv_ean 8424450253069
tlv_dim_product_x 7
tlv_dim_product_x_label Width
tlv_dim_product_x_unit mm
tlv_dim_product_y 1,000
tlv_dim_product_y_label Height
tlv_dim_product_y_unit mm
tlv_dim_product_z 7
tlv_dim_product_z_label Depth
tlv_dim_product_z_unit mm
tlv_weight_product_label Main product weight
tlv_weight_product 54
tlv_weight_product_unit g
tlv_gross_weight_label Gross weight
tlv_gross_weight 59
tlv_gross_weight_unit g
tlv_net_weight_label Net weight
tlv_net_weight_unit g
tlv_net_weight 54
tlv_1_type_pack Reel
tlv_1_type_pcs_pack m
tlv_1_pcs_pack 500

Mounting details

DETAIL VIEW OF THE DATA CABLE SECTION

  1. Inner conductor
  2. Inner conductor isolation
  3. Shielding foil
  4. Outer shielding braid
  5. Outer sheath