The wishlist name can't be left blank
DK6000A data cable U/UTP Cat 6A Cca LSFH 23AWG

DK6000A data cable U/UTP Cat 6A Cca LSFH 23AWG

DK6000A data cable U/FTP Cat 6A Cca LSFH 23AWG

Category-6A and Cca Euroclass data cable, U/FTP type (Foiled pairs), with copper conductor and LSFH sheath (Low Smoke Free of Halogen), white colour (RAL 9010).
It achieves a bandwidth up to 650 MHz (higher than the 500 MHz specified by the standard).
Supplied in a 500m wood reel.
Ref. 219302
Product Sheet
EAN13: 8424450214749
SKU
219302
Highlights
  • U/FTP Unfoiled FTP Cable (foiled pairs)
  • Solid copper inner conductor (23AWG)
  • Compatible with PoE/PoE+ (Power over Ethernet) technology, allowing the cable to power network devices
  • PE (Polyethylene) copper conductor insulation, 1.30mm diameter
  • Aluminium foil + polyester between foil and outer cable sheath
  • CuSn ground cable
  • LSFH (Low Smoke Free of Halogen) outer sheath, 0.70mm thick and 6.9mm diameter
  • 79% nominal speed
  • Certified according to the applicable standards as defined in the available declarations of conformity and performance

Discover

Category 6A

Data cable category Cat 6A (augmented) has its origins on Cat 6 and it is backwards compatible, with the standards of the inferior categories (Cat 6/5e and Cat 3). Category 6A evolves over category 6, allowing to achieve transmission frequencies of up to 500 MHz (in each pair) and 10 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T, 1000BASE-T and 10GBASE-T compliant systems.

Our category 6A cables are characterized for:

  • Comply with TIA/EIA-568B.2-1
  • Transfer rate up to 10Gbps
  • Frequency range of up to 650 MHz (higher than the 500 MHz specified by the standard)
  • Nominal impedance of 100 ohms
  • Maximum resistance per conductor below 9.38 ohms/100m

Compatibility of RJ45 connectors with Televes data cables:

Reference 219602 219701 219901 219910 212201   2123   212302 212305 212310 212101 219302 219312 219313 219322
Female connectors 209901/209907 OK OK OK OK OK OK OK OK OK X X X X X
209905 OK OK OK OK OK OK OK OK OK X X X X X
209921/209925 OK OK OK OK OK OK OK OK OK X X OK OK X
209926 OK OK OK OK OK OK OK OK OK X X OK OK X
209903 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209923 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
209929/209501 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
Male connectors
209902 OK OK OK OK OK OK OK OK OK X X X X X
209961/209962 OK OK OK OK OK OK OK OK OK X X X X X
209904 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209906 OK OK OK OK OK OK OK OK OK X X X X X
209965/209966 OK OK OK OK OK OK OK OK OK X X X X X
209922 OK* OK* OK OK* OK* OK* OK* OK* OK* X X OK OK X
209924 OK* OK* OK OK* OK* OK* OK* OK* OK* OK* OK OK* OK* OK

OK Compatible
OK* Compatible, but there are better choices
X Incompatible
** Mechanical compatibility


ModelDK6000A
TypeU/FTP
EuroclassCca
Euroclass: Smoke Productions1a
Euroclass: Flaming dropletsd1
Euroclass: Aciditya1
CategorieCat 6A
Transmission bandwidth650MHz
Transfer rate10Gbps
Conductor Diametermm0.55
Conductor MaterialSolid copper
Conductor type AWG23
Conductor isolation Diametermm1.3
Conductor isolation MaterialPolyethylene
Crucifix fillerNo
Shielding foil of pairsAluminium + Polyester
Drain wire Diametermm0.4
Drain wire MaterialTinned copper (CuSn)
Outer sheath Diametermm6.9
Outer sheath MaterialLSFH
Outer sheath Thicknessmm0.7
Rip cordNo
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceOhm/100m < 9.38
Nominal speed%79
Working voltageV125
Operating temperature°C -25 ... 70
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31.25 MHz62.5 MHz100 MHz200 MHz250 MHz300 MHz400 MHz500 MHz600 MHz650 MHz
Attenuation (max.)dB/100m
2.1 3.8 5.3 5.9 7.5 8.4 9.4 10.5 15 19.1 27.6 31.1 34.3 40.1 45 ----
Attenuation (typ.)dB/100m
2 3.7 5 5.6 7.2 8.1 9.1 10.3 14.6 18.6 26.7 29.9 32.8 38.5 43.5 48.2 50.1
NEXT (min.)dB/100m
74.3 65.3 60.8 59.3 56.2 54.8 53.3 51.9 47.4 44.3 39.8 38.3 37.1 35.3 34 ----
NEXT (typ.)dB/100m
87.6 80.2 74.9 72.7 69.1 66.5 65.5 62 56.5 52.3 47.2 45.3 43.6 41.1 39.1 34.3 32.3
PS NEXT (min.)dB/100m
72.3 63.3 58.8 57.3 54.2 52.8 51.3 49.9 45.4 42.3 37.8 36.3 35.1 33.3 32 ----
PS NEXT (typ.)dB/100m
85.6 78.7 72.1 70.4 66.8 64.7 63.4 60.4 54.8 50.8 45.8 44 42.3 39.4 36.1 32.6 30.9
ACR-N (min.)dB/100m
72.2 61.5 55.5 53.4 48.7 46.4 43.9 41.4 32.4 25.2 12.2 7.2 2.8 -4.8 -12 ----
ACR-N (typ.)dB/100m
85.6 76.6 70 67.2 62.1 58.6 56.6 51.9 42 33.8 20.8 15.7 11 3.2 -3.6 -12.9 -17
PS ACR-N (min.)dB/100m
70.2 59.5 53.5 51.4 46.7 44.4 41.9 39.4 30.4 23.2 10.2 5.2 0.8 -6.8 -14 ----
PS ACR-N (typ.)dB/100m
83.6 75.1 67.1 64.9 59.8 56.7 54.5 50.4 40.3 32.3 19.2 14.2 9.6 1.3 -7.2 -15.5 -19.2
ACR-F (min.)dB/100m
67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 21.8 19.8 18.3 15.8 14 ----
ACR-F (typ.)dB/100m
81.6 69.5 63.6 61.7 58 56.3 54.7 53.3 51.9 48.4 36.8 36.8 37 32.1 29 31.3 32.4
PS ACR-F (min.)dB/100m
64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 18.8 16.8 15.3 12.8 11 ----
PS ACR-F (typ.)dB/100m
79.1 67.4 61.4 59.6 55.8 54.1 52.7 51.1 47.7 46.7 35 35.1 34 30.6 26.9 30.1 30.3
Return losses (min.)dB
20 23 24.5 25 25 25 24.3 23.6 21.5 20.1 18 17.3 16.8 15.9 15 ----
Return lossesdB
25.6 27.9 29.7 30.1 33.7 32.2 34.6 32.3 29.5 28.6 27 23.3 23.2 19.5 18.8 19.6 18.8

Physical data

Net weight: 49 g

Gross weight: 54 g

Width: 7 mm

Height: 1,000 mm

Depth: 7 mm

Main product weight: 49 g

Packing

Reel 500 m

Pallet 9000 m

More Information
tlv_tags

Category 6A

Data cable category Cat 6A (augmented) has its origins on Cat 6 and it is backwards compatible, with the standards of the inferior categories (Cat 6/5e and Cat 3). Category 6A evolves over category 6, allowing to achieve transmission frequencies of up to 500 MHz (in each pair) and 10 Gbps of throughput. It includes characteristics and specifications to avoid crosstalk and noise. This type of data cable can be used in 10BASE-T, 100BASE-T, 1000BASE-T and 10GBASE-T compliant systems.

Our category 6A cables are characterized for:

  • Comply with TIA/EIA-568B.2-1
  • Transfer rate up to 10Gbps
  • Frequency range of up to 650 MHz (higher than the 500 MHz specified by the standard)
  • Nominal impedance of 100 ohms
  • Maximum resistance per conductor below 9.38 ohms/100m

Compatibility of RJ45 connectors with Televes data cables:

Reference 219602 219701 219901 219910 212201   2123   212302 212305 212310 212101 219302 219312 219313 219322
Female connectors 209901/209907 OK OK OK OK OK OK OK OK OK X X X X X
209905 OK OK OK OK OK OK OK OK OK X X X X X
209921/209925 OK OK OK OK OK OK OK OK OK X X OK OK X
209926 OK OK OK OK OK OK OK OK OK X X OK OK X
209903 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209923 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
209929/209501 OK* OK* OK OK* OK* OK* OK* OK* OK* OK OK OK* OK* OK
Male connectors
209902 OK OK OK OK OK OK OK OK OK X X X X X
209961/209962 OK OK OK OK OK OK OK OK OK X X X X X
209904 OK* OK* OK OK* OK* OK* OK* OK* OK* OK X X X X
209906 OK OK OK OK OK OK OK OK OK X X X X X
209965/209966 OK OK OK OK OK OK OK OK OK X X X X X
209922 OK* OK* OK OK* OK* OK* OK* OK* OK* X X OK OK X
209924 OK* OK* OK OK* OK* OK* OK* OK* OK* OK* OK OK* OK* OK

OK Compatible
OK* Compatible, but there are better choices
X Incompatible
** Mechanical compatibility

tlv_reflog CAT6AL500W
tlv_tabla_especificaciones
ModelDK6000A
TypeU/FTP
EuroclassCca
Euroclass: Smoke Productions1a
Euroclass: Flaming dropletsd1
Euroclass: Aciditya1
CategorieCat 6A
Transmission bandwidth650MHz
Transfer rate10Gbps
Conductor Diametermm0.55
Conductor MaterialSolid copper
Conductor type AWG23
Conductor isolation Diametermm1.3
Conductor isolation MaterialPolyethylene
Crucifix fillerNo
Shielding foil of pairsAluminium + Polyester
Drain wire Diametermm0.4
Drain wire MaterialTinned copper (CuSn)
Outer sheath Diametermm6.9
Outer sheath MaterialLSFH
Outer sheath Thicknessmm0.7
Rip cordNo
Spark TestVac3000
Nominal impedanceΩ100
Conductor resistanceOhm/100m < 9.38
Nominal speed%79
Working voltageV125
Operating temperature°C -25 ... 70
Frequencies
1 MHz4 MHz8 MHz10 MHz16 MHz20 MHz25 MHz31.25 MHz62.5 MHz100 MHz200 MHz250 MHz300 MHz400 MHz500 MHz600 MHz650 MHz
Attenuation (max.)dB/100m
2.1 3.8 5.3 5.9 7.5 8.4 9.4 10.5 15 19.1 27.6 31.1 34.3 40.1 45 ----
Attenuation (typ.)dB/100m
2 3.7 5 5.6 7.2 8.1 9.1 10.3 14.6 18.6 26.7 29.9 32.8 38.5 43.5 48.2 50.1
NEXT (min.)dB/100m
74.3 65.3 60.8 59.3 56.2 54.8 53.3 51.9 47.4 44.3 39.8 38.3 37.1 35.3 34 ----
NEXT (typ.)dB/100m
87.6 80.2 74.9 72.7 69.1 66.5 65.5 62 56.5 52.3 47.2 45.3 43.6 41.1 39.1 34.3 32.3
PS NEXT (min.)dB/100m
72.3 63.3 58.8 57.3 54.2 52.8 51.3 49.9 45.4 42.3 37.8 36.3 35.1 33.3 32 ----
PS NEXT (typ.)dB/100m
85.6 78.7 72.1 70.4 66.8 64.7 63.4 60.4 54.8 50.8 45.8 44 42.3 39.4 36.1 32.6 30.9
ACR-N (min.)dB/100m
72.2 61.5 55.5 53.4 48.7 46.4 43.9 41.4 32.4 25.2 12.2 7.2 2.8 -4.8 -12 ----
ACR-N (typ.)dB/100m
85.6 76.6 70 67.2 62.1 58.6 56.6 51.9 42 33.8 20.8 15.7 11 3.2 -3.6 -12.9 -17
PS ACR-N (min.)dB/100m
70.2 59.5 53.5 51.4 46.7 44.4 41.9 39.4 30.4 23.2 10.2 5.2 0.8 -6.8 -14 ----
PS ACR-N (typ.)dB/100m
83.6 75.1 67.1 64.9 59.8 56.7 54.5 50.4 40.3 32.3 19.2 14.2 9.6 1.3 -7.2 -15.5 -19.2
ACR-F (min.)dB/100m
67.8 55.8 49.7 47.8 43.7 41.8 39.8 37.9 31.9 27.8 21.8 19.8 18.3 15.8 14 ----
ACR-F (typ.)dB/100m
81.6 69.5 63.6 61.7 58 56.3 54.7 53.3 51.9 48.4 36.8 36.8 37 32.1 29 31.3 32.4
PS ACR-F (min.)dB/100m
64.8 52.8 46.7 44.8 40.7 38.8 36.8 34.9 28.9 24.8 18.8 16.8 15.3 12.8 11 ----
PS ACR-F (typ.)dB/100m
79.1 67.4 61.4 59.6 55.8 54.1 52.7 51.1 47.7 46.7 35 35.1 34 30.6 26.9 30.1 30.3
Return losses (min.)dB
20 23 24.5 25 25 25 24.3 23.6 21.5 20.1 18 17.3 16.8 15.9 15 ----
Return lossesdB
25.6 27.9 29.7 30.1 33.7 32.2 34.6 32.3 29.5 28.6 27 23.3 23.2 19.5 18.8 19.6 18.8
tlv_ean 8424450214749
tlv_dim_product_x 7
tlv_dim_product_x_label Width
tlv_dim_product_x_unit mm
tlv_dim_product_y 1,000
tlv_dim_product_y_label Height
tlv_dim_product_y_unit mm
tlv_dim_product_z 7
tlv_dim_product_z_label Depth
tlv_dim_product_z_unit mm
tlv_weight_product_label Main product weight
tlv_weight_product 49
tlv_weight_product_unit g
tlv_gross_weight_label Gross weight
tlv_gross_weight 54
tlv_gross_weight_unit g
tlv_net_weight_label Net weight
tlv_net_weight_unit g
tlv_net_weight 49
tlv_1_type_pack Reel
tlv_1_type_pcs_pack m
tlv_1_pcs_pack 500
tlv_2_pcs_pack 9000
tlv_2_type_pack Pallet
tlv_2_type_pcs_pack m

Mounting details

DETAIL VIEW OF THE DATA CABLE SECTION

  1. Inner conductor
  2. Inner conductor isolation
  3. Shielding foil
  4. Drain wire
  5. Outer sheath