The wishlist name can't be left blank

SK2005plus Coaxial cable, 18AtC Cca Euroclass, A Class shielded

RG-6 coaxial cable with both conductors made of copper (Cu/Cu) and an outstanding braid coverage (60%). Triple shielded (TSH) cable, equipped with a second foil for extra shielded. An 18AtC cable with UV-resistant LSFH sheath.

Ref. 414211
EAN13: 8424450207468
Highlights
  • Copper inner conductor and copper braid
  • Class A shielded
  • Cca-s1b,d2,a2 Euroclass

Main features
  • External UV-resistant LSFH sheath, black colour
  • 75 Ohm characteristic impedance
  • 250m wooden reel

Discover

Class A Trishield (TSH) coaxial cable

With three shielding layers (Trishield), this cables provide the highest immunity to interference thanks to its very high shielding. Recommended in cases of high electromagnetic noise levels.

They belong in EN 50117 standard Class A, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 5 mΩ/m
  • For 30 MHz - 1000 MHz => SA > 85 dB
  • For 1000 MHz - 2000 MHz => SA > 75 dB
  • For 2000 MHz - 3000 MHz => SA > 65 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.


ModelSK2005plus
Cable typeRG-6
StandardEN 50117-10-2
EuroclassCca
Euroclass: Smoke Productions1b
Euroclass: Flaming dropletsd2
Euroclass: Aciditya2
ClassA
Inner conductor Diametermm1
Inner conductor MaterialCopper (Cu)
Inner conductor ResistanceOhm/km < 22
Dielectric Diametermm4.6
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorOrange RAL 1007
Overlapped foilAluminium + Polyester
Braid MaterialTinned copper (CuSn)
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)7
Braid Dimensions: strand diameter (Ø)mm0.1
Braid ResistanceOhm/km < 14
Braid Coverage%60
2nd foilYes
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmNo
Outer sheath Diametermm6.7
Outer sheath MaterialLSFH, UV-resistant
Outer sheath Thicknessmm0.3
Minimum bending radiusmm33.5
Transfer impedance (5-30MHz)mΩ /m < 5
1GHz shieldingdB > 85
Spark TestVac3000
CapacitancepF/m54
ImpedanceΩ75
Velocity ratio%84
Operating temperature°C -25 ... 70
Atenuacion 5MHzdB/m0.02
Atenuacion 47MHzdB/m0.05
Atenuacion 54MHzdB/m0.05
Atenuacion 90MHzdB/m0.06
Atenuacion 200MHzdB/m0.09
Atenuacion 500MHzdB/m0.14
Atenuacion 698MHzdB/m0.17
Atenuacion 800MHzdB/m0.18
Atenuacion 862MHzdB/m0.19
Atenuacion 950MHzdB/m0.2
Atenuacion 1000MHzdB/m0.21
Atenuacion 1220MHzdB/m0.23
Atenuacion 1350MHzdB/m0.25
Atenuacion 1750MHzdB/m0.28
Atenuacion 2050MHzdB/m0.3
Atenuacion 2150MHzdB/m0.31
Atenuacion 2200MHzdB/m0.32
Atenuacion 2300MHzdB/m0.32
Atenuacion 2400MHzdB/m0.33
Atenuacion 3000MHzdB/m0.36

Physical data

Net weight: 48 g

Gross weight: 48 g

Packing

Reel 250 m

Pallet 7500 m

More Information
tlv_tags

Class A Trishield (TSH) coaxial cable

With three shielding layers (Trishield), this cables provide the highest immunity to interference thanks to its very high shielding. Recommended in cases of high electromagnetic noise levels.

They belong in EN 50117 standard Class A, according to their structural properties:

  • For 5 MHz - 30 MHz => TI < 5 mΩ/m
  • For 30 MHz - 1000 MHz => SA > 85 dB
  • For 1000 MHz - 2000 MHz => SA > 75 dB
  • For 2000 MHz - 3000 MHz => SA > 65 dB

Where the transfer impedance (TI) defines how effective the shielding is at low frequencies, while the shielding attenuation (SA) defines it in the 30 MHz-to-3000 MHz range.

tlv_tabla_especificaciones
ModelSK2005plus
Cable typeRG-6
StandardEN 50117-10-2
EuroclassCca
Euroclass: Smoke Productions1b
Euroclass: Flaming dropletsd2
Euroclass: Aciditya2
ClassA
Inner conductor Diametermm1
Inner conductor MaterialCopper (Cu)
Inner conductor ResistanceOhm/km < 22
Dielectric Diametermm4.6
Dielectric MaterialFoam polyethylene (PEE)
Dielectric ColorOrange RAL 1007
Overlapped foilAluminium + Polyester
Braid MaterialTinned copper (CuSn)
Braid dimensions: No. of carriers (Nc)16
Braid Dimensions: No. of strands per carrier (Ns)7
Braid Dimensions: strand diameter (Ø)mm0.1
Braid ResistanceOhm/km < 14
Braid Coverage%60
2nd foilYes
2nd foil glued to the dielectricNo
Petrol-JellyNo
Anti-migrating filmNo
Outer sheath Diametermm6.7
Outer sheath MaterialLSFH, UV-resistant
Outer sheath Thicknessmm0.3
Minimum bending radiusmm33.5
Transfer impedance (5-30MHz)mΩ /m < 5
1GHz shieldingdB > 85
Spark TestVac3000
CapacitancepF/m54
ImpedanceΩ75
Velocity ratio%84
Operating temperature°C -25 ... 70
Atenuacion 5MHzdB/m0.02
Atenuacion 47MHzdB/m0.05
Atenuacion 54MHzdB/m0.05
Atenuacion 90MHzdB/m0.06
Atenuacion 200MHzdB/m0.09
Atenuacion 500MHzdB/m0.14
Atenuacion 698MHzdB/m0.17
Atenuacion 800MHzdB/m0.18
Atenuacion 862MHzdB/m0.19
Atenuacion 950MHzdB/m0.2
Atenuacion 1000MHzdB/m0.21
Atenuacion 1220MHzdB/m0.23
Atenuacion 1350MHzdB/m0.25
Atenuacion 1750MHzdB/m0.28
Atenuacion 2050MHzdB/m0.3
Atenuacion 2150MHzdB/m0.31
Atenuacion 2200MHzdB/m0.32
Atenuacion 2300MHzdB/m0.32
Atenuacion 2400MHzdB/m0.33
Atenuacion 3000MHzdB/m0.36
tlv_ean 8424450207468
tlv_dim_product_x 0
tlv_dim_product_x_label Width
tlv_dim_product_x_unit mm
tlv_dim_product_y 0
tlv_dim_product_y_label Height
tlv_dim_product_y_unit mm
tlv_dim_product_z 0
tlv_dim_product_z_label Depth
tlv_dim_product_z_unit mm
tlv_weight_product_label Main product weight
tlv_weight_product_unit Array
tlv_gross_weight_label Gross weight
tlv_gross_weight 48
tlv_gross_weight_unit g
tlv_net_weight_label Net weight
tlv_net_weight_unit g
tlv_net_weight 48
tlv_1_type_pack Reel
tlv_1_type_pcs_pack m
tlv_1_pcs_pack 250
tlv_2_pcs_pack 7500
tlv_2_type_pack Pallet
tlv_2_type_pcs_pack m

Mounting details

DETAIL VIEW OF THE COAXIAL CABLE SECTION

A-Inner conductor
B-Dielectric
C-Foil
D-Braid
E-Second foil
F-Outer sheath

Cookies use